Telecom generators are backup power equipment specifically designed for the telecommunications industry to ensure continuous power supply for communication networks during outages. They are not ordinary generators, but highly reliable, highly automated power protection systems.
 
I. Characteristics of Telecom Generators
The characteristics of telecom generators can be summarized as high reliability, fully automatic operation, monitorable, and low interference. They are not ordinary generators, but specialized power backup systems designed to ensure uninterrupted communication.
 
 
II. Huaquan Power is a professional telecom generators manufacturer in China
Huaquan Power was established in 2010, and the company's business covers multiple fields including power generation equipment, new energy storage equipment, high and low voltage complete sets of equipment, and power engineering. It has built three major brands: "HQ-POWER," "HUAQUAN," and "Huaquan." Currently, the company has developed into a strong global brand in the power industry, with total global sales exceeding 1 million units.
Huaquan Power has large-scale, standardized production lines specifically for the telecommunications industry, ensuring consistent product quality and fast order delivery.
Huaquan Power deeply integrates telecommunications generator manufacturing technology with the specific operation and maintenance requirements of the communications industry, providing specialized products that are "highly reliable, intelligent, and monitorable." Relying on its extensive service network, it offers telecommunications operators cost-effective, reliable, one-stop power solutions.
 
III. Advantages of Telecom Generators
1. Uninterrupted Power: Can automatically switch power in seconds to ensure mobile signals and networks remain uninterrupted during any power outage, safeguarding communication lifelines.
2. Self-Operated: Unattended operation with remote monitoring. The system allows real-time status checks and fault alerts from the backend, eliminating the need for on-site personnel, making maintenance intelligent and efficient.
3. Quiet and Compliant: Telecom generators are designed with a quiet operation, low noise, and clean emissions, making them suitable for installation near residential areas without disturbing residents and meeting environmental standards.
4. Strong and Reliable: Telecom generators are specifically designed for harsh outdoor environments, resistant to extreme cold, heat, wind, and rain, with a low failure rate, offering greater stability and cost savings over long-term use.
 
Precautions for Using Telecom Generators
 
IV. Daily and Periodic Maintenance Precautions for Telecom Generators
1. Regular Test Run Precautions
Even if the mains power has never been interrupted, the telecom g enerator must be automatically started under load for 15-30 minutes every week or every two weeks.
Purpose: Lubricate the internal engine components, prevent battery discharge, remove carbon deposits, verify ATS switching functionality, and ensure the entire system is in a "hot standby" state.
2. Telecom Generator Fuel System Management:
Fuel quality: Use clean diesel that meets standards; in extremely cold areas, use the appropriate anti-freeze diesel.
Fuel level monitoring: Combine remote monitoring with manual inspections to ensure the fuel tank level is always above the minimum requirement.
Prevent fuel deterioration: Diesel can age and breed microorganisms. A plan should be established to replace or cycle stored fuel within 12-18 months and regularly clean the telecom generator fuel tank.
3. Battery Maintenance:
Regularly check the voltage, electrolyte specific gravity, and terminal corrosion of the telecom generator's starting battery.
Use an intelligent charger to prevent overcharging or undercharging. Strengthen inspections in cold areas.
4. Telecom Generator Cooling and Air Intake System:
Check coolant levels and quality, and replace periodically.
Keep the air filter clean and replace it regularly. Ensure that the air intake and exhaust openings are unobstructed.
5. Lubricating Oil (Engine Oil):
Change engine oil and oil filters according to running hours or periodically, and use the specified type of oil.
 
V. Precautions for Operating Telecom Generators
1. Load Test: During trial runs or actual power supply, try to operate with the actual load to avoid long-term "light load" or "no load" operation, which can cause carbon buildup in the telecom generator.
2. Monitor Instruments: While the telecom generator is running, pay attention to the parameters on the control panel, such as voltage, frequency, current, oil pressure, and water temperature, to ensure they are normal.
3. Abnormal Situations: Do not force a restart immediately if an alarm or fault shutdown occurs. First, check the fault codes on the control panel and contact a professional for troubleshooting.
4. Record Operating Logs: Keep detailed records of each start-up, operation, and shutdown of the telecom generator, including the time, reasons, operating parameters, and any abnormal conditions.
 
VI. Telecom Generators Safety and Compliance Precautions
1. Electrical Safety:
All installation, wiring, and maintenance must be carried out by licensed professional electricians.
Do not touch the equipment with wet hands while the telecom generator is running.
Ensure the telecom generator grounding system is sound and effective.
2. Fire Safety:
It is strictly forbidden to store flammable or explosive materials in the telecom generator room or installation area.
Equip with an adequate number of fire extinguishers.
Telecom generator fuel storage must comply with safety regulations.
3. Warning Signs:
Post safety signs such as "High Voltage Danger," "No Smoking or Open Flames," and "Do Not Approach While Running" in prominent locations.
4. Compliance with Regulations:
Abide by local environmental and safety regulations regarding noise, emissions, and fuel storage, and undergo regular inspections.
 
VII. Q&A on Telecom Generators
1. How to choose the power of a telecom generator?
You need to calculate the total power consumption of all base station equipment (main equipment, air conditioning, transmission, etc.) and leave a margin of 30%-50% to cope with load fluctuations and future expansion.
2. How does a telecom generator achieve "automatic switching" power supply?
The ATS monitors the mains in real time. Once an anomaly occurs, it immediately sends a signal to start the telecom generator. After the voltage stabilizes, it automatically switches the load to the generator power, all without human intervention.
3. What are the key points of telecom generator maintenance?
Regularly change the generator oil and the three filters (air filter, engine filter, fuel filter)
Check the coolant, battery, and belt tension
Clean the generator's air intake and exhaust vents to ensure proper ventilation
 
VIII. Application Areas of Telecom Generators
1. Mobile Communication Base Stations: Telecom generators provide primary or backup power for 4G/5G base stations, which is a core application scenario.
2. Core Data Centers and Server Rooms: Ensure uninterrupted operation of critical equipment such as switches and servers.
3. Optical Cable Relay Stations and Microwave Stations: Telecom generators provide stable power in remote locations or where grid electricity is unavailable.
4. Emergency Communication Vehicles and Satellite Ground Stations: Telecom generators serve as on-vehicle power sources for mobile or temporary communication facilities.
5. Broadcast and Television Transmitters: Ensure uninterrupted signal transmission.
 
Telecom generators are specifically used to ensure power security across all communication links, from core data centers to edge base stations, and from fixed installations to mobile emergency setups. Users should choose a suitable telecom generator based on their specific operational needs.
More information about telecom generators: https://hq-power.net/


【Hot news】
  Sales hotline: +8615905360672     Email address: huaquan@huaquanpower.com
  WhatsApp: +8615905360672        Official website: https://www.huaquanpower.com
  Production Base: No. 11666 Guting Street, Economic Development Zone,Weifang City, Shandong Province
  Company Name: SHANDONG HUAQUAN POWER CO.,LTD

Huaquan Group All rights reserved sitemaps