Proper maintenance of marine diesel generator is important to ensure reliable power supply and safe operation of ships. Offshore use presents unique challenges with saltwater exposure, constant vibration, and tight cabin conditions. Therefore, the daily maintenance of marine diesel generator is very important, and the following introduction is for users' reference.
Daily Inspection Routine of marine diesel generator
Begin with visual checks for oil/fuel leaks and unusual noises during operation. Verify coolant levels and inspect belts for proper tension. The raw water cooling system requires particular attention to prevent salt deposits and corrosion. Always keep the marine diesel generator exterior clean to facilitate leak detection and heat dissipation.
Electrical Components of marine diesel generator
Check battery terminals for corrosion and maintain proper electrolyte levels. Tighten all electrical connections to avoid voltage fluctuations. Regularly test automatic start-stop systems and alarm functions.
Long-Term Preservation of marine diesel generator
During prolonged standby periods, run the marine diesel generator monthly under load to prevent internal condensation. Apply anti-corrosion coatings to exposed metal surfaces and keep the engine room ventilated to reduce humidity.
Lubrication Management of marine diesel generator
Use marine-grade oils specified by the manufacturer and monitor oil quality regularly. Contaminated lubricants accelerate bearing wear and reduce marine diesel generator efficiency. Change oil filters according to service intervals, ensuring proper disposal of used oil to meet environmental regulations.
Fuel System Care of marine diesel generator
Drain water separators daily to prevent microbial growth in fuel tanks. Inspect fuel lines for cracks and ensure injectors are free from carbon buildup. For vessels operating in tropical waters, fuel waxing prevention measures are advisable.
By adhering to these fundamental practices, operators can significantly extend the service life of marine diesel generator while minimizing unplanned downtime. Always consult the equipment manual for model-specific requirements and maintain detailed maintenance records for regulatory compliance.